Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
新會員
|
剛剛打電話問0800-717-718 MicroChip是建議我將那兩個電阻短路 可是 接下來出現的問題是 Verifying configuration memory... ICDWarn0050: Config memory at 0xF80006 does not match programmed value. Value programed = 0x0, Value read = 0x310F ICDWarn0050: Config memory at 0xF80008 does not match programmed value. Value programed = 0x0, Value read = 0x330F ICDWarn0050: Config memory at 0xF8000A does not match programmed value. Value programed = 0x3, Value read = 0x7 Connecting to debug executive ...Programming succeeded MPLAB ICD 2 Ready 這是否意味著設定上還是有問題呢?
發表於: 2004/12/13 14:58
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
版主
|
dsPIC在-x80006 & 8 的位址是沒有用到的,0x8000A 是Code Protected 設定。
請先將dsPIC20F2010先erase後在檢查IC是否為BLANK的,如果都無法清乾淨那就換一個試試看吧! 按上面的顯示應該是可以進入Debug模式的,要是真的還是有問題找高雄的FAE送修。
發表於: 2004/12/13 17:23
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
版主
|
以前的一個問題供參考:
----------------------------------------------------------------------- 忘了問,是否有使用到 QEI ??? 在ICD2 Debug Mode 暫存器 "ADPCFG" 會被設定為 0xFFFF,PORTB 及 QEI 功能可以呈現出來。 但在 Stand Alone Mode 下,Power-On Reset 會將暫存器 "ADPCFG" 清除為0x0000,結果會將導致QEI無法在類比模式的輸入PIN工作。 解決方式是將PORTB設為數位模式,方式如下: ADPCFGbits = 0x00nn; (where nn is the value for configuring the PORTB pins to digital)
發表於: 2004/12/15 17:22
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
新會員
|
那该怎么样確定可以抓到30F2010的ID呢 谢谢
發表於: 2005/10/19 11:47
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
版主
|
ICD2 正常連線時就會顯示出 dsPIC30F2010 的 ID 及Reversion
發表於: 2005/10/24 18:23
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
新會員
|
我試過有電阻r23,r36及沒有的ICD2,可是都還是下列的訊息
Programming Target... ICDWarn0052: MPLAB ICD 2 cannot validate a target device. Please make sure that the target device is connected and properly powered. Select "OK" to continue, or "CANCEL" to abort the operation ...Validating configuration fields ICDWarn00051: Illegal configuration memory value 0x0 at address 0xf80008 (field RES2). Would you like ICD2 to set this field to the default value? Ignoring this warning may corrupt the device. ...Erasing Part ...Programming Programming Executive ...Verifying Programming Executive ICD0161: Verify failed (MemType = Test, Address = 0x800000, Expected Val = 0x40080, Val Read = 0x0) ICD0275: Programming failed. MPLAB ICD 2 Ready 可能是什麼雲因呢
發表於: 2005/11/21 17:30
|
|||
|
Re: ICD2連線dsPIC30F2010的問題
|
||||
---|---|---|---|---|
版主
|
IC 壞了, ICD2 掛了,兩著都有可能,找代理商的 FAE 測
看看是否有壞以便送修。
發表於: 2005/11/23 11:13
|
|||
|